Integration with Warp and M
This page describes a method for integration of Dynamo, Warp and M to be able to take advantage of...
Warp's
- streamlined preprocessing
- robust CTF estimation procedures for tilt-series data
Dynamo's
- automated tilt-series alignment
- geometric picking tools
- flexible subtomogram averaging procedures
M's
- multi-particle refinement
- half-map regularisation by denoising
Contents
Overview
- Preprocess from multi-frame micrographs to tilt-series using Warp
- Align tilt-series using [Dynamo]
- Generate downscaled tomograms in warp
- Pick particles in Dynamo and run first alignments
- Reextract unbinned particles in warp using [dynamo2m]
- Run alignments/classifications in dynamo or relion
- Run multi-particle refinements in M
The last steps can be repeated to further improve final reconstruction quality
preprocess
Preprocess your multi-frame micrographs in warp following the guide [here]
Bad images should be deselected in Warp at this stage.
This stage is finished once you have your tilt-series in the imod folder
If you collected your data in Tomo rather than SerialEM and don't have mdoc files, you can try [mdocspoofer]
align tilt-series
Tilt series can either be aligned in IMOD or using dynamo's new tilt series alignment tools
A function to automate the alignment of datasets with fiducials and convert all necessary metadata for import into warp is provided as [| autoalign_dynamo].
Once you've followed the setup from that page, simply navigate to the imod directory generated by warp and run
dautoalign4warp(<pixel_size_angstrom>, <fiducial_diameter_nm>, <nominal_rotation_angle>, <output_folder>)
The output folder is a folder which will contain all of your alignments for this dataset.
Briefly, tilt-series are aligned in Dynamo with the automated procedure. The fiducial positions are then converted into an IMOD model file and tiltalign is run on this to calculate the necessary transforms to apply to the tilt series in the format Warp wants.
generate downscaled tomograms
Tomograms are reconstructed at a larger pixel size in Warp for picking using the [tomography task dialogue] in Warp.
Choose to also generate a deconvolved version, we will use this for visualisation.
Generate a catalogue using the function warp2catalogue()provided in [autoalign_dynamo]
warp2catalogue(<warp_reconstruction_folder>, <pixel_size_angstrom>)
pick particles in dynamo
Pick particles using your favourite type of model through the catalogue created in the previous step.
Make sure to crop particles from the catalogue directly, this will make sure that even though you picked particles on filtered volumes for visualisation the particles are cropped from the unfiltered tomograms.
You can choose to run first sets of alignments on these downscaled particles to find which particles you would like to use for later refinements